Menu

PDF version

Technical Data Sheet (TDS)

SMP-840 Contractor's Polymer Adhesive

Moisture cured Polymer Wood Flooring Adhesive

Special features

  • Moisture cured wood adhesive
  • Non-etching
  • Requires no moisture testing (some restrictions apply)
  • Cleans easily even after cured

Product Description
STAUF SMP-840 Contractor's Polymer is an advanced formula polymer designed for professional wood flooring installation. It replaces isocyanate-containing urethane adhesives. It is ozone and environmentally safe since there are no hazardous materials contained in it. Because there is no water or solvent present, it will not cause dimensional changes to wood flooring. This adhesive is waterproof when fully cured and will not dissolve if it gets wet. However, it will not prevent moisture-related damage to wood flooring.
The adhesive spreads easily and has a non-slump formula that will help insure contact and adhesive transfer. It allows fast installation even with complicated patterns due to its strong green grab. There is no flash time required, so installation can commence immediately. Rolling is neither required nor recommended. It offers superior flexibility and is designed to keep the flooring in place, yet allow for normal movement during seasonal changes to the flooring.
Pre-Installation Checklist
A successful installation requires proper preparation of the subfloor. Read and understand all applicable guidelines and technical data sheets before installation. Follow industry standards and flooring manufacturers' recommendations for subfloor moisture content, design, layout, and application of flooring materials. All flooring material's backing must be solid, sound, and free of anti-adherents. All slab constructions must meet the specific requirements of the floor covering to be installed.
Sub Floor Examination
Prior to installation, the subfloor must be checked according to NWFA installation guidelines. It must be solid and sound, flat, permanently dry, clean, free of chaps, indentations, and anti-adherents, and resistant to pressure and tension. The moisture content of all floors must be measured before installation.
All wood floors should have 6-9% moisture content at installation. There should be no more than a 4-5% variance in moisture content between the wood flooring and any wood subfloor. See NWFA guidelines and the wood flooring manufacturer's recommendations for details.
No moisture testing is required for installation of engineered wood floor in new construction as long as a new STAUF #12 clip-on blade is used for every pail, there is 100% coverage of the adhesive on the subfloor, the spread rate does not exceed 35 SF/gal and concrete floors are at least 30 days old.
Sub Floor Preparation
Depending on the type and condition of the subfloor, a mechanical treatment (e.g. mechanical brushing, grinding, or sanding) may be required. The intensity of such work must be determined at the site by the installer. Dust, paint, residual adhesives, or other surface contaminants must be removed by suitable means. Cleaning the surface with an industrial vacuum cleaner is recommended. Cracks and gaps must be filled with concrete crack filler unless they are expansion joints. Level when necessary to 3/16 inches within 10 feet. Heated subfloors, gypcrete, wooden subfloors, levelers, patches, and lightweight concrete must be primed. Fast curing cementitious leveling or patching compounds might reduce the flash and work time of water-based products due to absorption.
Installation Procedure
Spread the adhesive with the appropriate notched trowel. Avoid excessive adhesive thickness by passing the trowel evenly through the adhesive at a 45° angle. There is no flash time, so installation should begin immediately. Lay the flooring into the adhesive, correctly position it and press down firmly. Rolling is neither required nor recommended. Be sure to check the boards at regular intervals to ensure a good adhesive transfer from subfloor to flooring is achieved. Bowed boards or boards over low spots should be weighted down until the adhesive cures.
Limitations
When using other than STAUF products in conjunction with STAUF primers, sealers, leveling compounds, or adhesives, STAUF denies any and all responsibility for any ensuing problems and/or damages without prior written authorization from STAUF.
Do not install solid wood below grade. Do not use on concrete with curing agents or sealers. Do not install wood flooring with a moisture reading above 9%. Do not use adhesive as a leveling material. This adhesive will not prevent moisture-related damages to wood flooring caused by flooding, busted pipes, etc., or where moisture conditions are in excess of limitations outlined in the Subfloor Examination.
This adhesive is mold and mildew-resistant and water resistant when fully cured. However, it will not prevent moisture-related damages to wood flooring unless it is used as a moisture barrier (if applicable) within the limitations set forth in the Technical Data Sheet.
In case of an accident, injury, spill, or exposure, see SDS for information. Consult the Technical Data Sheet at www.staufusa.com for updated information.
The foregoing representations are based on the results of our most current product and material testing within a controlled environment and are of a non-obligatory advisory nature only. As such, they do not constitute an express or implied warranty of any kind including the Warranty of Merchantability and/or Fitness for a Particular Purpose. Because we have no control over the actual quality of workmanship, materials used, and worksite conditions, STAUF USA LLC will in no event be liable for any incidental and/or consequential damages. Therefore, we strongly recommend that prior on-site testing be conducted to refer to and study the suitability of the product for the intended purpose. With the release of this Technical Information Sheet, all its prior versions become invalid. For warranty and warranty disclaimer information please see our Limited Lifetime Warranty @ www.staufusa.com
General Features
  • LEED qualified
  • Contains no water
  • Contains no chlorinated solvents
  • Nonflammable
  • High solids content
  • Ozone friendly
  • Special polymer will not etch floors finish
  • Freeze/thaw stable
  • Contains no isocyanates
Installation Features
  • Wet lay - no flash time required
  • Non-slump formula
  • No rolling required
  • Does not cause cupping of wood flooring
  • Long open time
  • Spreads easily
  • Higher temp and RH will shorten drying time
  • No risk of sensitization
  • Cleans with urethane cleaner
Long Term Features
  • Resistant against aging
  • Suitable for radiant heat systems with primer
  • Allows normal dimensional changes in wood flooring
  • Adhesive is waterproof when cured
Approved Flooring
  • Engineered Wood Flooring
  • Parquet
  • Bamboo or Eucalyptus NOT approved
  • Underlayments
Approved Subfloors
  • Concrete Slabs
  • OSB (underlayment grade)
  • Plywood (underlayment grade)
  • Ceramic Tiles
  • Stone, Terrazzo
  • Cured Leveling Compounds
  • Radiant Heated Subfloors
  • Epoxy Sealers (100% solid, cured)
Approved Sealers
  • STAUF ACS-210 True-Seal
  • STAUF ERP-270 Perma-Seal
Approved Leveling Compounds
  • STAUF ULC-500 Universal Leveling Compound
  • STAUF SLC-540 Self Leveling Compound
  • STAUF QFF-560 Quick Feather Float
  • STAUF RLC-580 Fiber Level
Approved Trowels and Spread Rate
  • Engineered Floors-#5 (3/16 x 1/4 x 3/8 in) up to 60 SF/gal.
  • Parquet-#3 (5/32 x 1/8 x 3/16 in) up to 70 SF/gal.
  • Moisture Barrier-#12: up to 35 SF/gal. (Must use one per pail)
  • Underlayments-#15 (3/32 x 3/32 x 3/32 in) up to 130 SF/gal.
Cure Time until Normal Traffic
  • Between 24 and 48 hours
Clean-Up
  • Use acetone while wet
  • Use plastic scraper and terry cloth when dry
Temperature Range during Installation
  • 50-90F (10-32C)
Relative Humidity Range during Installation
  • 30% - 80%
Packaging Size
  • 4 gal. Plastic Pail
  • 36 per pallet
Color
  • Cream
VOC (Rule 1168 calc.) [g/L]
  • zero
Storage
  • Dry
Shelf Life
  • 9 Months in original, unopened container
Shear Strength
  • 217 psi (1.5 N/mm²)
Open Time30% R/H50% R/H80% R/H
50�F/10�C2 hours 1-3/4 hours 1-1/4 hour 
70�F/21�C1-3/4 hours 1-1/2 hour 1 hour 
90�F/32�C70 mins 60 mins. 45 mins. 